Send Message
  • English
Home ProductsMiniature Cartridge Fuse

3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead

Certification
China Dongguan Linkun Electronic Technology Co., Ltd. certification
China Dongguan Linkun Electronic Technology Co., Ltd. certification
Customer Reviews
Good quality product , very fast shipping , great price !!!

—— Phoebe

I'm Online Chat Now

3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead

3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead
3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead 3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead 3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead

Large Image :  3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead

Product Details:
Place of Origin: China DongGuang
Brand Name: LinKun
Certification: UL ROHS CCC CUL VDE
Model Number: 331 311 Series
Document: Product Brochure PDF
Payment & Shipping Terms:
Minimum Order Quantity: 1000PCS
Price: Negotiation
Packaging Details: 1000pcs/reel
Delivery Time: 5-7 days
Payment Terms: L/C, D/A, D/P, T/T, Western Union
Supply Ability: 100,000 pieces/month

3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead

Description
Main Characteristics:: Miniature Cartridge Fuse; Fast-Acting(F) Rated Current:: 250mA-12A; 500mA-15A
Rated Voltage:: 250V AC Operating Temperature:: -55℃ To +125℃
Standard:: UL248-14; IEC60127-3 Fast Acting: Glass Tube
End Caps:: Nickel-plated Brass Axial Leads:: Tin-plated Copper Wires
Tube:: Glass Tube High Light:: 250V Quick Blow Fuse, 3.6 X10mm Quick Blow Fuse, Cartridge 3.6 X10mm Fuse
Highlight:

3.6 X10mm Glass Tube Fuse

,

15A Glass Tube Fuse

,

Axial Lead Glass Tube Fuse

Product Description:

Electrical Axial Lead 250V Cartridge Quick Blow Fast Acting 3.6x10mm Tube Glass Fuse

 

3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead 0

 

Series:3.6x10mm tube glass fuse
Product keyword:NO.331/3.6*10mm 3.6x10mm glass fuse

 

331 series are fast-acting and low breaking capacity fuses, suitable for 250V AC voltage, breaking capacity less than 63A protection circuit.
331 series fuses are mainly used in lighting, power supply and power adapters.

 

Time-current characteristics: fast fusing (F)
Dividing ability: 50A@125Vac[250mA~6.3A], 35A or 10In@250Vac[250mA~6.3A], 50A@250Vac[7~10A]


Standard: UL 248-14


Accredited: cURus, CQC, PSE, TUV


Material: shell-glass tube, metal cap-nickel-plated brass, lead cap-nickel-plated cap, tin-plated copper wire


Operating temperature: -55℃ ~ +125℃


Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds (manual welding)


Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;


Storage condition: +10℃ ~ +60℃;The annual average relative humidity is less than 75%, and the relative humidity reaches 95% for a maximum of not more than 30 days

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 1

 

Time vs Current Characteristics: UL248-14
Rated Current 150% 210% 275% 400% 1000%
250mA~5A >1h <30min 10ms~3s 3ms~300ms ≤20ms
6.3A~10A >1h <30min 50ms~10s 5ms~400ms ≤20ms

 

Electrical Characteristics at 25℃
Amp
Code
Ratede
Current
Max
Voltage
Drop(mV)

 

Max.Power
Dissipation
(mW)
Typical
cold Resistance(mΩ)
Nominal Melting
I²t(A²sec)
Breaking
Capacity
Approvals
             
cULus
PSE TUV CCC
              125V 250V 250V 250V 250V
0500 500mA 350 459 137.80 0.384

 

 
50A/125V AC
35A or 10ln/250V AC







 

0630 630mA 320 529 95.23 0.656
0800 800mA 300 630 123.75 1.00
1100 1.00A 280 375 55.00 2.25
1125 1.25A 280 919 43.00 2.57
1160 1.60A 250 1050 37.80 2.89
1200 2.00A 240 1260 26.00 2.25
1250 2.50A 200 1313 19.90 6.75
1315 3.15A 180 1488 15.00 13.69
1400 4.00A 160 1680 11.22 22.09
1500 5.00A 150 1969 8.78 39.69
1630 6.30A 150 1969 7.00 62.41
1800 8.00A 150 1969 5.83 92.16
50A/125V AC
50A/250V AC
2100 10.00A 150 1969 4.80 156

 

Note: 1.Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)
2.The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 2

 

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 0

 

Series:3x10mm tube glass fuse
Product keyword:NO.311/3*10mm fast acting glass fuse

 

Series 311 are fast blow and low breaking capacity fuses, suitable for 250V AC voltage, breaking capacity less than 50A protection circuit.
311 series fuses are mainly used in lighting, power supply and power adapters.

 

Time-current characteristics: fast-acting fusing (F)
Dividing ability: 50A@250Vac / 50A@125Vac

 

Standard: UL 248-14


Accredited: cULus


Material: shell - glass tube, metal cap - nickel plated brass, lead cap - nickel - plated cap, tin - plated copper wire


Operating temperature: -55℃ ~ +125℃


Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds (manual welding)


Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;


Storage condition: +10℃ ~ +60℃;The annual average relative humidity is less than 75%, and the relative humidity reaches 95% for a maximum of not more than 30 days

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 4

Time vs Current Characteristics: UL248-14
Rated Current 100% 200%
250mA~12A >4h <5s

 

Electrical Characteristics at 25℃
Amp Code
Ratede Current
Rated Voltage
Typical
cold Resistance(mΩ)
Nominal Melting
I²t(A²sec)
Breaking
Capacity
Approvals
   



 

 

 

 

 

 

 

 

 

250V AC













 

     
 
 
 
 
 
 
 
 
 
50A @ 250V AC
50A @ 125V AC












 
cULus
0250 250mA 540 0.040
125V
250V
0300 300mA 335 0.078
0500 500mA 182 0.225
0630 630mA 145 0.357
0800 800mA 131 0.576
1100 1.00A 70.0 0.940
1125 1.25A 62.8 1.56
1150 1.50A 52.0 3.45
1200 2.00A 31.5 6.25
1250 2.50A 32.3 4.00
1300 3.00A 22.0 11.9
1315 3.15A 23.1 4.97
1400 4.00A 15.5 7.84
1500 5.00A 12.0 20.3
1630 6.30A 9.73 34.5
1700 7.00A 8.20 48.8
1800 8.00A 7.80 64.0
2100 10.00A 6.31 81.0
2120 12.00A 5.31 132

 

Note: 1.Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)
2.The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.

 

Cartridge 250V Quick Blow Fuse 3.6 X10mm Fuse Fast Acting Electrical Axial Lead 5

 
3.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead 63.6 X10mm Glass Tube Fuse Fast Blow 250V 100MA-15A Axial Lead 7Miniature Cartridge Fuse

The Miniature Cartridge Fuse is a small and compact fuse designed for various electrical applications. It is also known as a Tiny, Micro, or Compact Cartridge Fuse. This fuse is used to provide overcurrent protection in circuits with low voltage ratings.

Product Description

The Miniature Cartridge Fuse is a type of fuse that has axial leads, which are tin-plated copper wires. This design allows for easy installation and replacement in applications with limited space. The tin-plated copper wires also provide excellent conductivity and corrosion resistance, ensuring a stable and reliable electrical connection.

Storage Conditions

The recommended storage conditions for the Miniature Cartridge Fuse are between +10℃ to +60℃. It is important to store the fuse in a dry and well-ventilated area to prevent exposure to moisture, which can affect its performance.

Product Specifications
  • Rated Voltage: 250V AC
  • Standard: IEC 60127-2/Ⅱ; GB/T9364.7
  • Main Characteristics: Miniature Cartridge Fuse; Fast-Acting(F)

The Miniature Cartridge Fuse is compliant with IEC 60127-2/Ⅱ and GB/T9364.7 standards, ensuring its quality and safety. It is designed to be fast-acting, which means it will quickly interrupt the circuit in case of overcurrent, protecting the circuit and its components from damage.

Applications

The Miniature Cartridge Fuse is commonly used in various electronic devices and appliances, such as computers, televisions, and home appliances. It is also suitable for use in automotive, industrial, and medical equipment.

Conclusion

The Miniature Cartridge Fuse is a reliable and compact fuse that provides overcurrent protection in low voltage circuits. Its axial leads and tin-plated copper wires make it easy to install and ensure a stable connection. With its fast-acting characteristic and compliance with international standards, the Miniature Cartridge Fuse is a top choice for various electrical applications.

 

 

Contact Details
Dongguan Linkun Electronic Technology Co., Ltd.

Contact Person: Ms. Huang

Tel: 13423305709

Send your inquiry directly to us (0 / 3000)