Product Details:
|
Breaking Capacity:: | High | Maximum Current: | 5/40(A) |
---|---|---|---|
Holding Current: | 5/30(A) | Fuse Speed: | F/fast |
Usage:: | Thermal | Rated Voltage:: | 250V |
Case:: | Metal | Shape:: | Pointed Tubular |
Operating Temperature: | 85/250(℃) | High Light:: | 250V 5A-40A Overheating Protector |
Highlight: | 250V Ceramic Thermal Fuse,5A Ceramic Thermal Fuse |
Electric Fan Motor Axial Ceramic Case Resistor Type Temperature Fuse Thermal Cutoff Fuse
Structure
The thermal fuse is composed of ceramic shell, low melting point alloy wire, special resin, pin copper wire and sealing resin.
Apprearance
The marking must be clear; the sealing resin should fill the mouth and it is acceptable; the lead tin-plated layer is good; there is no oxidized black spot damage; the shell has no damage marks, perforations, etc.
No. | Rated operating temperature Tf(℃) |
Hold temperature Tc(℃) |
Limit temperature Tm (℃) |
Measured operating temperature (℃) |
Rated voltage (V) | Rated current In(A) |
||||||||||
Y20 | 115 | 87 | 150 | 112±3 | 250 | 2 |
Name | Thermal Fuse | Applicable Standards | |||||||||||||||
Test items | Unit | Safety standard | Testing equipment | ||||||||||||||
Action temperature detection | ℃ | +0 TF -10 |
thermotank | ||||||||||||||
High pressure test | V | 1000+2 times the rated voltage | Withstand voltage tester | ||||||||||||||
Insulation resistance detection | MΩ | >2 | Digital Megger | ||||||||||||||
Internal resistance detection | Ω | <0.028 | Bridge resistance tester | ||||||||||||||
High pressure test after temperature check | V | >500 | Withstand voltage tester | ||||||||||||||
Insulation resistance test after temperature test | MΩ | >0.2 | Digital Megger | ||||||||||||||
Distortion detection | Each lead is bent 90° at a distance of 10mm from the thermal fuse, and then twisted in the opposite direction by 180° without damaging the components. | Manual operation |
Experimental Method
The experimental conditions are temperature 25±10℃, humidity 65±15%M
1 Action humidity accuracy: Rely on the IE691: 1995 inspection method and measure with the built-in silicone oil pool in the thermostat.
2 Size: Measure the finished product with a micrometer/vernier ruler.
3 Appearance: visual inspection.
4 Insulation resistance: Measure the finished product with SP-3A digital megohmmeter, and measure the voltage DC500V.
5 Withstand voltage: Use the ZNY-12 withstand voltage test to determine the finished product, which takes 1 minute.
6 Tensile force: Measure the finished product with a push-pull tester, and the pin bears 1.5 pounds of pulling force for 10 minutes without damaging the components.
7 Torsion: Bend the lead at 10mm at 90°C, and then reverse it at 180°C without damaging the component.
Test Requirements
1. Rated operating temperature (Tf): The temperature at which the thermal fuse is tested according to the standard method to change its conductive state. (The Japanese Electrical Appliances Management Law stipulates that the tolerance range is ±7℃ for operation).
2. Measured operating temperature: The temperature fuse is heated in the silicone oil bath at a rate of 0.5-1°C per minute, and the fusing temperature obtained when the detection current is less than 100MA. It is the actual temperature of the thermal fuse.
3. Holding temperature (Tc): The maximum temperature at which the thermal fuse can maintain 168 hours without changing its conductive state when passing the rated current.
4. Limit temperature (Tm): The maximum temperature at which the thermal fuse can withstand 10 minutes without reconnection.
5. Rated voltage (Ur): The highest working voltage of the thermal fuse.
The Thermal Cutoff Fuse is a type of fusible link that has been specifically designed to protect your electrical devices from overheating and potential fire hazards. With a high breaking capacity, durable metal casing, and a wide range of rated currents and temperatures, this fuse is the perfect solution for ensuring the safety and longevity of your electronic equipment.
The Thermal Cutoff Fuse boasts a high breaking capacity, meaning it can handle large amounts of electrical current without breaking or melting. This makes it suitable for use in a variety of devices, from small household appliances to large industrial machinery.
The Thermal Cutoff Fuse comes in a compact size of 62x4mm, making it easy to install in tight spaces and ensuring minimal disruption to your device's design. Despite its small size, this fuse packs a powerful punch and can effectively protect your equipment from thermal overloads.
This Thermal Fuse is available in two different rated currents - 10A and 16A. This means you can choose the appropriate fuse for your specific device, ensuring optimal performance and protection.
The case of the Thermal Cutoff Fuse is made of metal, providing superior durability and protection against external factors such as heat and moisture. This ensures the fuse can withstand extreme conditions and continue to function effectively.
The Thermal Cutoff Fuse has a wide operating temperature range, from 76℃ to 260℃. This means it can effectively detect and cut off power when the temperature exceeds the rated temperature, preventing potential damage to your device.
The Thermal Cutoff Fuse is also referred to as a Thermal Shutoff Fusible Link, as it works by breaking the electrical circuit when the temperature reaches a dangerous level. This ensures the device is immediately cut off from power, preventing any potential hazards.
This Thermal Cutoff Fuse is also commonly known as a Thermal Fuse Thermal Cutoff, as it operates based on the principle of thermal cutoff. It is designed to provide a fail-safe mechanism to protect your device from overheating and potential fire hazards.
In conclusion, the Thermal Cutoff Fuse is an essential component for ensuring the safety and longevity of your electronic equipment. With its high breaking capacity, compact size, durable metal casing, and wide range of rated currents and temperatures, this fuse is the ultimate protection for your devices against thermal overloads. Choose the Thermal Cutoff Fuse for peace of mind and reliable performance.
Product Name | Thermal Cutoff Fuse |
---|---|
Type | Thermal Fuse Protector, Thermal Cutoff Switch, Cutoff Thermal Link |
Rated Voltage | 250V |
Case | Metal |
Shape | Resistor |
Usage | Thermal |
Rated Current | 10A, 16A |
Breaking Capacity | High |
Size | 62x4mm |
Rated Temperature | 76℃ to 260℃ |
Brand Name: LinKun
Model Number: RY RYB Series
Place of Origin: China DongGuang
Shape: Resistor
Breaking Capacity: High
Case: Metal
Rated Temperature: 76℃ to 260℃
Usage: Thermal
Thermal Cutoff Fuse, also known as Thermal Fuse Protector or Thermal Cutoff Switch, is a type of safety device that is used to protect electronic devices from overheating. It is designed to cut off the power supply to the device when the temperature reaches a certain level, preventing damage and potential hazards.
Thermal Cutoff Fuse is widely used in various electronic devices and appliances, including but not limited to:
The Thermal Cutoff Fuse is made up of a metal casing with a small piece of fuse inside. When the temperature rises to a critical level, the fuse will melt and break the electrical connection, cutting off the power supply to the device. As the temperature cools down, the fuse will solidify again, allowing the device to function normally.
The breaking capacity of the Thermal Cutoff Fuse is high, ensuring that even in extreme conditions, it will be able to cut off the power supply effectively. The metal case provides extra protection and durability, making it suitable for use in various environments.
LinKun is a trusted brand in the field of thermal protection devices. Our RY RYB Series Thermal Cutoff Fuse is manufactured in China DongGuang, using high-quality materials and advanced technology to ensure its reliability and effectiveness.
Our Thermal Cutoff Fuse has a rated temperature range of 76℃ to 260℃, making it suitable for a wide range of applications. It is also compact in size and easy to install, making it a convenient choice for both manufacturers and end-users.
With LinKun Thermal Cutoff Fuse, you can have peace of mind knowing that your devices are protected from overheating and potential hazards.
Brand Name: LinKun
Model Number: RY RYB Series
Place of Origin: China DongGuang
Case: Metal
Usage: Thermal
Size: 62x4mm
Shape: Resistor
Rated Voltage: 250V
Our Thermal Cutoff Fuse, also known as Temperature Sensitive Circuit Breaker, Thermal Overload Switch, or Thermal Fuse, is a reliable and customizable solution for protecting electrical equipment from overheating.
At LinKun, we offer a wide range of options for our customers to customize their Thermal Cutoff Fuses to meet their specific needs. With our expertise in thermal technology and our commitment to quality, we are able to provide the following services:
As a trusted manufacturer based in China DongGuang, we pride ourselves on delivering high-quality Thermal Cutoff Fuses that meet international standards. Our team of experts will work closely with you to understand your requirements and provide the best solution for your thermal protection needs.
Don't compromise on safety and reliability for your electrical equipment. Choose LinKun's Thermal Cutoff Fuse for customized and superior thermal protection. Contact us today to learn more about our services and how we can help you.
The Thermal Cutoff Fuse is packaged in a sturdy cardboard box to ensure safe transportation and storage. The box is labeled with the product name, model number, and specifications for easy identification.
Inside the box, the Thermal Cutoff Fuse is wrapped in protective plastic and placed in a foam insert to prevent any damage during shipping. The foam insert is designed to fit the shape and size of the fuse, providing additional protection.
The box also includes a user manual and any necessary installation accessories. The user manual contains important information on how to properly install and use the Thermal Cutoff Fuse.
For international shipping, the box is labeled with the necessary customs information and documentation. Our team takes great care in packaging the product to ensure it arrives safely and in good condition.
Once packaged, the Thermal Cutoff Fuse is shipped via a reliable and trusted shipping carrier. The shipping options and costs may vary depending on the destination and urgency of the order.
Upon delivery, please inspect the package for any signs of damage. If any damage is found, please contact us immediately for assistance.
Thank you for choosing our Thermal Cutoff Fuse. We take pride in providing high-quality products and ensuring they arrive safely to our customers.
Contact Person: Ms. Huang
Tel: 13423305709